Q7

No "AUT selection" window is shown

Details

Description

Test Steps:

1. Use Q7 as an AUT;
2. Launch AUT;
3. Open Test Case editor and run it by clicking "Replay" button - it should pass;
4. Close AUT by clicking X button;
5. Press "Replay" button. No "AUT selection" window occurs. The following error will be shown in Execution view:

Connection is not Available
at java.io.DataInputStream.readInt(Unknown Source)
at org.eclipse.ecl.internal.core.EMFStreamPipe.take(EMFStreamPipe.java:61)
at org.eclipse.ecl.client.tcp.EclTcpSession.writeOutput(EclTcpSession.java:111)
at org.eclipse.ecl.client.tcp.EclTcpSession.access$3(EclTcpSession.java:108)
at org.eclipse.ecl.client.tcp.EclTcpSession$1.run(EclTcpSession.java:66)
at java.lang.Thread.run(Unknown Source)

6. Press Replay one more time - window will be shown.

Activity

Hide
Evgeny Tarasenko added a comment - 13/Dec/11 4:44 PM

Look like fail of Q7 test "RunAUTByRunCommand" (http://build.xored.com/browse/Q7-Q7D11-182) related to this issue,
i reproduce it locally: reason of fail "Select Application Under Test" dialog is shown and Control Panel window is disabled.

Show
Evgeny Tarasenko added a comment - 13/Dec/11 4:44 PM Look like fail of Q7 test "RunAUTByRunCommand" (http://build.xored.com/browse/Q7-Q7D11-182) related to this issue, i reproduce it locally: reason of fail "Select Application Under Test" dialog is shown and Control Panel window is disabled.
Hide
ystrot added a comment - 14/Dec/11 9:00 PM

Done. However fail of RunAUTByRunCommand doesn't depend to this issue (see QS-1621).

Show
ystrot added a comment - 14/Dec/11 9:00 PM Done. However fail of RunAUTByRunCommand doesn't depend to this issue (see QS-1621).