Q7

Object is not selected in Vozone Explorer at the replaying q7 test

Details

  • Type: Bug Bug
  • Status: Closed Closed
  • Priority: Major Major
  • Resolution: Fixed
  • Affects Version/s: 1.2.16
  • Fix Version/s: 1.2.17
  • Component/s: Runtime
  • Labels:
  • Test Mode:
    Manual

Description

"Device definitions are divided by supplier when importing generated MLI" test was failed on http://build.xored.com/browse/Q7-Q7D12-DGFD-723.

Execution failed on line 35 at column 25
Caused by:Execution failed. Cause: 'The control "Finish" is disabled.'

Failed on the following steps:
1. Select "Network Diagrams" in Vozone Explorer and select "Import/Import MLI XML file" in context menu
In "Import MLI XML files" window location is not set and "Finish" button is disabled.

This situation is unstable, but sometimes it reproduced on local machine.

Activity

Hide
anastasia.ahramenko added a comment - 19/Mar/13 10:57 AM

Similar tests are modified.

Show
anastasia.ahramenko added a comment - 19/Mar/13 10:57 AM Similar tests are modified.
Hide
Andrey Sobolev added a comment - 25/Feb/13 10:40 AM

Test is fixed.

Nastya cloud you also please verity over similar tests.

Show
Andrey Sobolev added a comment - 25/Feb/13 10:40 AM Test is fixed. Nastya cloud you also please verity over similar tests.
Hide
Andrey Sobolev added a comment - 25/Feb/13 10:38 AM

Issue is related to Vozone implementation.

Following code do files generation, but content of Vozone Explorer could be updated a little bit later, so test could pass, but could fail.

get-view "Vozone Explorer" | get-tree | select "Company\\/Project/Network Diagrams/Diagram" | double-click -nowait
with [get-editor Diagram | get-diagram] {
    with [get-edit-part -name Diagram] {
        mouse-move 173 218 button3 -height 609 -width 1034
        mouse-press 173 218 button3 -height 609 -width 1034
        mouse-release 173 218 button3 2097152 -height 609 -width 1034
    }
    get-menu "Generate Network MLI..." | click
}
get-window "Select Location for the MLI Files" | get-button OK | click

Test could be fixed adding following line:

get-view "Vozone Explorer" | get-tree | select "Company\\/Project/MLI" | get-menu Refresh | click
Show
Andrey Sobolev added a comment - 25/Feb/13 10:38 AM Issue is related to Vozone implementation. Following code do files generation, but content of Vozone Explorer could be updated a little bit later, so test could pass, but could fail.
get-view "Vozone Explorer" | get-tree | select "Company\\/Project/Network Diagrams/Diagram" | double-click -nowait
with [get-editor Diagram | get-diagram] {
    with [get-edit-part -name Diagram] {
        mouse-move 173 218 button3 -height 609 -width 1034
        mouse-press 173 218 button3 -height 609 -width 1034
        mouse-release 173 218 button3 2097152 -height 609 -width 1034
    }
    get-menu "Generate Network MLI..." | click
}
get-window "Select Location for the MLI Files" | get-button OK | click
Test could be fixed adding following line:
get-view "Vozone Explorer" | get-tree | select "Company\\/Project/MLI" | get-menu Refresh | click